First simulation
In this example, you will estimate the electric field in gray matter when a TMS coil is placed over C3. You will use the public Ernie head model and its EEG landmarks to specify the placement. The coil will sit 4 mm above the scalp with its handle pointing toward Cz. Complete Installation first.


In this example, C3 defines the scalp position and Cz defines the handle direction.
-
Locate the head model. Download and extract the SimNIBS 4 example dataset. Run the following example from the directory containing
m2m_ernie. SimNIBS example datasetDirectoryernie/
Directorym2m_ernie/
- ernie.msh
Directoryeeg_positions/
- EEG10-10_UI_Jurak_2007.csv
-
Run the simulation. Save the following as
first_simulation.py.Python from pathlib import Pathfrom cunibs import Coil, Placement, Subjectfrom cunibs.head import read_subject_capmodel_dir = Path("m2m_ernie")cap = read_subject_cap(model_dir)coil = Coil.load("MagStim_D70")placement = Placement(center_mm=cap["C3"], handle_mm=cap["Cz"], distance_mm=4.0)with Subject.from_mesh(model_dir / "ernie.msh") as subject:result = subject.simulate(coil, placement, didt=1.0e6)print(f"Peak gray matter field: {result.peak_magnE():.3f} V/m")print(f"Peak location (mm): {result.peak_location_mm()}")print(f"Focality at 50%: {result.focality(0.5) * 1e6:.3f} cm³")result.save("ernie_c3.h5")python first_simulation.py -
Read the result. The script prints a peak field, its location in the mesh coordinate system, and a tissue volume in cubic centimetres. It also writes
ernie_c3.h5. You can reopen it withFieldResult.load("ernie_c3.h5").
didt is the rate of change of coil current in A/s. The example sets it to 1,000,000 A/s. The resulting field scales with the current slope. See coil models for how to specify it and Interpret results for the definition of focality.
The guides use the variables defined in this example. Run their simulation code within a with Subject.from_mesh(model_dir / "ernie.msh") as subject: block, or add it inside the block above.